- User Convenience
All functions of existing PC software are installed in OPTIZEN Alpha, making it faster and more convenient.
- Incredible Speed
Fast and flexible software delivers the best result with analytical speeds up to 1.5 times that of existing products.
- Rapid Service
Quick services are available as OPTIZEN Alpha is made in Korea from design conception to manufacturing based on the unique technology of K LAB Co., Ltd.
- Extensive Scalability
OPTIZEN Alpha is designed for high-precision/high-resolution measurement in widebands from ultraviolet to visible light and can be used in various applications.
- Compact Size
Compact OPTIZEN Alpha enhances the efficiency of the experimental space.
- Sensuous Design
Now, you can enjoy a greater level of pleasure with a sensuous design.
Main Charateristics
- A world-class measurement performance
- Wide-size color screen (ALPHA: 8”)
- Various cell compatibility and fast cell type choice
- Automatic measurement of lots of samples by equipping multi-cell.
- Convenient voice service and volume control
- Emotional design
Modes for Measurement
- Photometric Mode
This mode allows you to measure the absorbance and concentration of a sample at a specific wavelength.
- Quantitation Mode
This mode allows you to quantitatively analyze a sample using the calibration curve.
- Spectrum Mode
This mode allows you to acquire the absorption or transmission spectrum in the desired wavelength band.
- Kinetics Mode
This mode allows you to measure the absorbance or transmittance of a sample over time.
Photometric Mode
- · In this mode, the absorbance (Abs) (or transmittance (%T)) at a specific wavelength can be easily measured.
- · The factor (K) value can be set to allow a simple quantitative test (C = K × A) on a sample to be performed making it possible for absorbance (Abs) measurement.
- · Up to 8 wavelengths can be set, and the absorbance at each wavelength is measured automatically.
- · Automatic analysis for up to 7 samples is possible using the multi-cell holder.
Quantitation Mode
- · It is a mode that can measure and manage the calibration curve by utilizing the multi-cell holder.
- · Quantitative analysis for a sample of interest can be performed using a calibration curve made by up to 7 concentrations of the sample.
- · Four types of calibration curves including linear (zero-crossing), linear, quadratic, and cubic types are provided.
- · Accurate calibration curve can be created with the values measured repeatedly for a maximum of 5 times.
Spectrum Mode
- · This mode allows the user to check the spectrum of the desired wavelength band.
- · Absorbance (Abs) and transmittance (%T) data can be switched using a shortcut key.
- · Automatic spectrum analysis for up to 7 samples (excluding the reference sample) is possible.
- · This mode includes the functions to zoom in the section and to find the Peak/Valley location of the spectrum.
Kinetics Mode
- · This mode allows the user to check the change in absorbance(or transmittance) over time at a specific wavelength.
- · This mode is measured at regular intervals, and the minimum interval that can be set is for 1 second.
- · This mode’s progresses during the measurement is displayed, and 24-hour measurement is possible.
- · The changes in the absorbance of 7 samples can be obtained automatically.
Photometrics System |
Double-beam type |
Monochromator |
Czerny-Turner type with 1200 lines/nm blazed grating |
Light Source |
WI lamp / D2 lamp |
Lamp interchange Wavelength |
340~410 nm (Default 370 nm) |
RMS noise |
Less than 0.00005 Abs (700 nm) |
Detector |
Silicon Photodiodes |
Spectral Bandwidth |
1.0 nm (190 to 1100 nm) |
Wavelength Range |
190 to 1100 nm |
Wavelength Display(Setting) |
0.05 nm |
Wavelength Accuracy |
±0.3 nm (For entire range)
±0.1 nm (656.1 nm) |
Wavelength Repeatability |
<± 0.1 nm |
Wavelength Slew Rate |
Approx. 25,000 nm/min |
Scanning Speed(Max) |
6,000 nm/min |
Photometric Range |
Absorbance : -4 to 4 A
Transmittance : 0 % to 400 % |
Photometric Accuracy |
±0.002 Abs at 0.5 Abs
±0.004 Abs at 1.0 Abs
±0.006Abs at 2.0Abs
(NIST930D/NIST1930 or equivalent) |
Photometric repeatability |
Less than ± 0.0002 at 0.5 Abs
Less than ± 0.0006 at 1.0 Abs
Less than ± 0.0010 at 2.0 Abs |
Baseline stability |
Less than 0.0003 Abs/hr
(700 nm, one hour after light source turned ON) |
Baseline flatness |
<± 0.0005 A
(1,100 to 190 nm, one hour after light source turned ON) |
Environmental requirements |
Temperature: 15 °C to 35 °C
Humidity: 30 % to 80 % |
Stray light |
Less than 1.00 %(198 nm KCl)
Less than 0.05 %(220 nm NaI)
Less than 0.05 %(340 nm NaNO2) |
RMS noise |
Less than 0.00005 Abs (700 nm) |
Standard cell Holder |
Automatic Rotary type 8-position Multi-Cell Holder |
Operating system(OS) |
Windows 10 (Embedded PC) |
Display |
8-inch color LCD with touch screen |
Control Options |
Onboard with built-in touchscreen
Computer (OPTIZEN View) |
Power Requirement |
AC 100-240 V, 50/60 Hz, 140 VA |
Dimensions(W*D*H) |
520 mm * 500 mm * 200 mm |
Weight(kg) |
14 kg |
PC Software |
(optional) OPTIZEN View for Windows®
(optional) OPTIZEN Secure™ |